1,096 research outputs found

    The puzzle of anomalously large isospin violations in η(1405/1475)→3π\eta(1405/1475)\to 3\pi

    Full text link
    The BES-III Collaboration recently report the observation of anomalously large isospin violations in J/ψ→γη(1405/1475)→γπ0f0(980)→γ+3πJ/\psi\to \gamma\eta(1405/1475) \to \gamma \pi^0 f_0(980)\to \gamma +3\pi, where the f0(980)f_0(980) in the ππ\pi\pi invariant mass spectrum appears to be much narrower (∼\sim 10 MeV) than the peak width (∼\sim50 MeV) measured in other processes. We show that a mechanism, named as triangle singularity (TS), can produce a narrow enhancement between the charged and neutral KKˉK\bar{K} thresholds, i.e., 2mK±∼2mK02m_{K^\pm}\sim 2m_{K^0}. It can also lead to different invariant mass spectra for η(1405/1475)→a0(980)π\eta(1405/1475)\to a_0(980)\pi and KKˉ∗+c.c.K\bar{K}^*+c.c., which can possibly explain the long-standing puzzle about the need for two close states η(1405)\eta(1405) and η(1475)\eta(1475) in ηππ\eta\pi\pi and KKˉπK\bar{K}\pi, respectively. The TS could be a key to our understanding of the nature of η(1405/1475)\eta(1405/1475) and advance our knowledge about the mixing between a0(980)a_0(980) and f0(980)f_0(980).Comment: 4 pages and 7 eps figures; Journal-matched versio

    Diagnostic Accuracy of CEUS LI-RADS for the Characterization of Liver Nodules 20 mm or Smaller in Patients at Risk for Hepatocellular Carcinoma.

    Get PDF
    Background: American College of Radiology contrast agent–enhanced US Liver Imaging Reporting and Data System (CEUS LI-RADS) was developed to improve the accuracy of hepatocellular carcinoma (HCC) diagnosis at contrast agent2enhanced US. However, to the knowledge of the authors, the diagnostic accuracy of the system in characterization of liver nodules 20 mm or smaller has not been fully evaluated. Purpose: To evaluate the diagnostic accuracy of CEUS LI-RADS in diagnosing HCC in liver nodules 20 mm or smaller in patients at risk for HCC. Materials and Methods: Between January 2015 and February 2018, consecutive patients at risk for HCC presenting with untreated liver nodules 20 mm or less were enrolled in this retrospective double-reader study. Each nodule was categorized according to the CEUS LI-RADS and World Federation for Ultrasound in Medicine and Biology (WFUMB)–European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) criteria. Diagnostic performance of CEUS LI-RADS and WFUMB-EFSUMB characterization was evaluated by using tissue histologic analysis, multiphase contrast-enhanced CT and MRI, and imaging follow-up as reference standard and compared by using McNemar test. Results: The study included 175 nodules (mean diameter, 16.1 mm 6 3.4) in 172 patients (mean age, 51.8 years 6 10.6; 136 men). The sensitivity of CEUS LR-5 versus WFUMB-EFSUMB criteria in diagnosing HCC was 73.3% (95% confidence inter-val [CI]: 63.8%, 81.5%) versus 88.6% (95% CI: 80.9%, 94%), respectively (P, .001). The specificity of CEUS LR-5 versus WFUMB-EFSUMB criteria was 97.1% (95% CI: 90.1%, 99.7%) versus 87.1% (95% CI: 77%, 94%), respectively (P = .02). No malignant lesions were found in CEUS LR-1 and LR-2 categories. Only two nodules (of 41; 5%, both HCC) were malignant in CEUS LR-3 category. The incidences of HCC in CEUS LR-4, LR-5, and LR-M were 48% (11 of 23), 98% (77 of 79), and 75% (15 of 20), respectively. Two of 175 (1.1%) histologic analysis2confirmed intrahepatic cholangiocarcinomas were categorized as CEUS LR-M by CEUS LI-RADS and misdiagnosed as HCC by WFUMB-EFSUMB criteria. Conclusion: The contrast-enhanced US Liver Imaging Reporting and Data System (CEUS LI-RADS) algorithm was an effective tool for characterization of small (≤20 mm) liver nodules in patients at risk for hepatocellular carcinoma (HCC). Compared with World Federation for Ultrasound in Medicine and Biology2European Federation of Societies for Ultrasound in Medicine and Biology criteria, CEUS LR-5 demonstrated higher specificity for diagnosing small HCCs with lower sensitivity

    Discriminating different scenarios to account for the cosmic e±e^\pm excess by synchrotron and inverse Compton radiation

    Full text link
    The excesses of the cosmic positron fraction recently measured by PAMELA and the electron spectra by ATIC, PPB-BETS, Fermi and H.E.S.S. indicate the existence of primary electron and positron sources. The possible explanations include dark matter annihilation, decay, and astrophysical origin, like pulsars. In this work we show that these three scenarios can all explain the experimental results of the cosmic e±e^\pm excess. However, it may be difficult to discriminate these different scenarios by the local measurements of electrons and positrons. We propose possible discriminations among these scenarios through the synchrotron and inverse Compton radiation of the primary electrons/positrons from the region close to the Galactic center. Taking typical configurations, we find the three scenarios predict quite different spectra and skymaps of the synchrotron and inverse Compton radiation, though there are relatively large uncertainties. The most prominent differences come from the energy band 104∼10910^4\sim 10^9 MHz for synchrotron emission and ≳10\gtrsim 10 GeV for inverse Compton emission. It might be able to discriminate at least the annihilating dark matter scenario from the other two given the high precision synchrotron and diffuse γ\gamma-ray skymaps in the future.Comment: published in Pr

    (S)-(+)-4-(Oxiran-2-ylmeth­oxy)-9H-carbazole

    Get PDF
    In the title compound, C15H13NO2, all atoms of the carbazole group are coplanar (r.m.s. deviation = 0.005 Å), and the dihedral angle between this plane and C—O—C plane of oxane group is 57.1 (4)°. The crystal packing is stabilized by an N—H⋯O hydrogen bond, resulting in infinite supra­molecular chains along [001]

    Characteristics of Traffic Flow at Nonsignalized T-Shaped Intersection with U-Turn Movements

    Get PDF
    Most nonsignalized T-shaped intersections permit U-turn movements, which make the traffic conditions of intersection complex. In this paper, a new cellular automaton (CA) model is proposed to characterize the traffic flow at the intersection of this type. In present CA model, new rules are designed to avoid the conflicts among different directional vehicles and eliminate the gridlock. Two kinds of performance measures (i.e., flux and average control delay) for intersection are compared. The impacts of U-turn movements are analyzed under different initial conditions. Simulation results demonstrate that (i) the average control delay is more practical than flux in measuring the performance of intersection, (ii) U-turn movements increase the range and degree of high congestion, and (iii) U-turn movements on the different direction of main road have asymmetrical influences on the traffic conditions of intersection

    5 GHz TMRT observations of 71 pulsars

    Full text link
    We present integrated pulse profiles at 5~GHz for 71 pulsars, including eight millisecond pulsars (MSPs), obtained using the Shanghai Tian Ma Radio Telescope (TMRT). Mean flux densities and pulse widths are measured. For 19 normal pulsars and one MSP, these are the first detections at 5~GHz and for a further 19, including five MPSs, the profiles have a better signal-to-noise ratio than previous observations. Mean flux density spectra between 400~MHz and 9~GHz are presented for 27 pulsars and correlations of power-law spectral index are found with characteristic age, radio pseudo-luminosity and spin-down luminosity. Mode changing was detected in five pulsars. The separation between the main pulse and interpulse is shown to be frequency independent for six pulsars but a frequency dependence of the relative intensity of the main pulse and interpulse is found. The frequency dependence of component separations is investigated for 20 pulsars and three groups are found: in seven cases the separation between the outmost leading and trailing components decreases with frequency, roughly in agreement with radius-to-frequency mapping; in eleven cases the separation is nearly constant; in the remain two cases the separation between the outmost components increases with frequency. We obtain the correlations of pulse widths with pulsar period and estimate the core widths of 23 multi-component profiles and conal widths of 17 multi-component profiles at 5.0~GHz using Gaussian fitting and discuss the width-period relationship at 5~GHz compared with the results at at 1.0~GHz and 8.6~GHz.Comment: 46 pages, 14 figures, 8 Tables, accepted by Ap

    Protection effect of sanguinarine on whole-body exposure of X radiation in BALB/c mice

    Get PDF
    To investigate the effects of sanguinarine (SAN) on acute radiation induced injury in mice, 45 mice were randomly divided into control, 10 Gy and SAN+10 Gy groups. Mice in the 10 Gy and SAN+10 Gy groups were exposed to single X-ray radiation with an accumulated dose of 10 Gy. Mice in the SAN+10 Gy group were administered intraperitoneally with 2.5 mg/kg body weight of SAN before radiation. Five days after radiation exposure, 5 mice from each group were sacrificed and samples of the small intestine, lung, spleen and liver were fixed for histopathological examinations. Compared with the 10 Gy group, radiation sickness was obviously delayed or attenuated in the SAN+10 Gy group. Survival analysis showed a significant difference between 2 radiation groups (PPara investigar os efeitos da sanguinarina (SAN) em lesões induzidas em ratos por radiação aguda, 45 ratos foram aleatoriamente divididos em grupo controle, grupo 10 Gy e grupo SAN+10 Gy. Os ratos dos grupos 10 Gy e SAN+10 Gy foram expostos à radiação de raio-X simples com uma dose acumulada de 10 Gy. Aos ratos do grupo SAN+10 Gy administraram-se, intraperitonealmente, 2.5 mg/kg de peso de SAN antes da radiação. Aos 5 dias de exposição à radiação, sacrificaram-se 5 ratos de cada grupo e retiraram-se amostras do intestino delgado, pulmões, baço e fígado para exames histopatológicos. Comparando com o grupo 10 Gy, a doença por radiação foi claramente atrasada e atenuada no grupo SAN+10 Gy. A análise de sobrevivência mostrou diferença significativa entre os dois grupos de radiação (
    • …
    corecore